Part Number |
Description |
QP40-DP01M30WG |
40G QSFP+ DAC passive cable 1m |
QP40-DP02M30WG |
40G QSFP+ DAC passive cable 2m |
QP40-DP03M30WG |
40G QSFP+ DAC passive cable 3m |
QP40-DP05M26WG |
40G QSFP+ DAC passive cable 5m |
QP40-DP07M26WG |
40G QSFP+ DAC passive cable 7m |
Q/4SFP+ DAC Specifications | |
Number of Lanes | Tx & Rx |
Channel Data Rate | 10.3125 Gbps |
Operating Temperature | 0 to + 70°C |
Storage Temperature | -40 to + 85°C |
Supply Voltage | 3.3 V nominal |
Electrical Interface | 38 pins edge connector(QSFP+)20 pins edge connector(SFP+) |
Management Interface | Serial, I2C |
Parameter |
Symbol |
Min |
Typ |
Max |
Units |
Notes |
Differential Impedance | Zd | 90 | 100 | 110 | ohm | |
Differential Input Return Loss | SDDXX | <-12+2* SQRT (f) with f in GHz | dB | 0.01~4.1GHz | ||
<-6.3+13*Log10/(f/5.5) with f in GHz | dB | 4.1~11.1GHz | ||||
Common Mode Output Return Loss | SCCXX | < -7+1.6*f with f in GHz | dB | 0.01~2.5GHz | ||
-3 | dB | 2.5~11.1GHz | ||||
Difference Waveform Distortion Penalty | dWDPc | 6.75 | dB | |||
VMA Loss | L | 4.4 | dB | |||
VMA Loss to Crosstalk Ratio | VCR | 32.5 | dB |
Pin | Logic | Symbol | Description |
1 | GND |
Ground |
|
2 | CML-I | Tx2n |
Transmitter Inverted Data Input |
3 | CML-I | Tx2p |
Transmitter Non-Inverted Data Input |
4 | GND |
Ground |
|
5 | CML-I | Tx4n |
Transmitter Inverted Data Input |
6 | CML-I | Tx4p |
Transmitter Non-Inverted Data Input |
7 | GND |
Ground |
|
8 | LVTTL-I | ModSelL |
Module Select |
9 | LVTTL-I | ResetL |
Module Reset |
10 | Vcc Rx |
+3.3V Power Supply Receiver |
|
11 | LVCMOS-I/O | SCL |
2-wire serial interface clock |
12 | LVCMOS-I/O | SDA |
2-wire serial interface data |
13 | GND |
Ground |
|
14 | CML-O | Rx3p |
Receiver Non-Inverted Data Output |
15 | CML-O | Rx3n |
Receiver Inverted Data Output |
16 | GND |
Ground |
|
17 | CML-O | Rx1p |
Receiver Non-Inverted Data Output |
18 | CML-O | Rx1n |
Receiver Inverted Data Output |
19 | GND |
Ground |
|
20 | GND |
Ground |
|
21 | CML-O | Rx2n |
Receiver Inverted Data Output |
22 | CML-O | Rx2p |
Receiver Non-Inverted Data Output |
23 | GND |
Ground |
|
24 | CML-O | Rx4n |
Receiver Inverted Data Output |
25 | CML-O | Rx4p |
Receiver Non-Inverted Data Output |
26 | GND |
Ground |
|
27 | LVTTL-O | ModPrsL |
Module Present |
28 | LVTTL-O | IntL |
Interrupt |
29 | Vcc Tx |
+3.3V Power supply transmitter |
|
30 | Vcc1 |
+3.3V Power supply |
|
31 | LVTTL-I | LPMode |
Low Power Mode |
32 | GND |
Ground |
|
33 | CML-I | Tx3p |
Transmitter Non-Inverted Data Input |
34 | CML-I | Tx3n |
Transmitter Inverted Data Input |
35 | GND |
Ground |
|
36 | CML-I | Tx1p |
Transmitter Non-Inverted Data Input |
37 | CML-I | Tx1n |
Transmitter Inverted Data Input |
38 | GND |
Ground |
Pin | Logic | Symbol | Description |
1 | VeeT | Module Transmitter Ground | |
2 |
LVTTL-O |
Tx_Fault | Module Transmitter Fault |
3 |
LVTTL-I |
Tx_Disable | Transmitter disable; Turns off transmitter laser output |
4 |
LVTTL-I/O |
SDA | 2-wire Serial Interface Data Line (Same as MOD-DEF2 in INF-8074i) |
5 |
LVTTL-I/O |
SCL | 2-wire Serial Interface Clock (Same as MOD-DEF1 in INF-8074i) |
6 | Mod_ABS | Module Absent, connected to VeeT or VeeR in the module | |
7 |
LVTTL-I |
RS0 | Rate Select 0, optionally controls SFP+ module receiver |
8 |
LVTTL-O |
Rx_LOS | Receiver Loss of Signal Indication (In FC designated as Rx_LOS and in Ethernet designated as Signal Detect) |
9 |
LVTTL-I |
RS1 | Rate Select 1, optionally controls SFP+ module transmitter |
10 | VeeR | Module Receiver Ground | |
11 | VeeR | Module Receiver Ground | |
12 |
CML-O |
RD- | Receiver Inverted Data Output |
13 |
CML-O |
RD+ | Receiver Non-Inverted Data Output |
14 | VeeR | Module Receiver Ground | |
15 | VccR | Module Receiver 3.3 V Supply | |
16 | VccT | Module Transmitter 3.3 V Supply | |
17 | VeeT | Module Transmitter Ground | |
18 |
CML-I |
TD+ | Transmitter Non-Inverted Data Input |
19 |
CML-I |
TD- | Transmitter Inverted Data Input |
20 | VeeT | Module Transmitter Ground |
Feature | Test Method | Performance |
Electrostatic Discharge (ESD) to the Electrical Pins | MIL-STD-883C Method 3015.7 | Class 1(>2000 Volts) |
Electromagnetic Interference (EMI) | FCC Class B | Compliant with Standards |
CENELEC EN55022 Class B | ||
CISPR22 ITE Class B | ||
RF Immunity (RFI) | IEC61000-4-3 | Typically Show no Measurable Effect from a 10V/m Field Swept from 80 to 1000MHz |
RoHS Compliance | RoHS Directive 2011/65/EU and it's Amendment Directives 6/6 | RoHS 6/6 compliant |
Version No. | Date | Description |
1.0 | 2018-3-1 | Preliminary datasheet |